Residual Stress Analysis of Composite Tubes Used for Kraft Recovery Boilers

 
 
Panel of tubes mounted for residual stress analysis (above)

Approach:

  • Determine residual stresses due to composite tube material, manufacturing, and service
  • Use results to develop and verify FEM models at room temperature
  • Employ the models to assess stress during boiler operation and to suggest alternative materials

 

 

 
Post weld heat-treatment was shown to remove the tensile stresses and is essential for successfully welding into panels  

Large tensil stresses were found, posing a serious problem for welding of tube panels

 

 

 

 

 

 

 

 

 

 

 

 

   
   

 Oak Ridge National Laboratory